nissan Workshop Repair Guides

Nissan and Datsun Workshop Service and Repair Manuals

Expansion Valve|Testing and Inspection|Page 3243 > < Expansion Valve|Testing and Inspection
Page 1
background image

Expansion Valve: Service and Repair

    When replacing evaporator, add 2.7 oz. of new refrigerant oil on 300ZX or 2.4 oz. on all other models. 

Fig. 15 Instrument panel attachment plate removal.

PULSAR & SENTRA

1.

Disconnect battery ground cable and discharge system refrigerant.

2.

Disconnect refrigerant lines from evaporator, plugging all openings, then remove piping grommet and cover.

3.

Remove passenger side instrument lower cover and glove compartment.

4.

Remove attachment plate from instrument panel, Fig. 15.

Fig. 16 Instrument panel cut lines.

Fig. 17 Instrument panel cut lines.

5.

Using hacksaw blade, cut instrument panel on cut lines, Figs. 16 and 17. Cover blower motor vent holes with tape before cutting and brush
shavings away from area around blower motor and remove tape after cutting.

6.

Remove blower motor unit.

7.

Remove cooling unit.

8.

Separate cooling unit case halves and remove evaporator.

9.

Disconnect and remove expansion valve.

10.

Reverse procedure to install, noting the following: 

a. Ensure that expansion valve is properly positioned.

Expansion Valve|Testing and Inspection|Page 3243 > < Expansion Valve|Testing and Inspection