JIS = Japan Industrial Standard, used for Japan produced batteries
CCA = Cold Cranking Amps, standard for North American produced batteries

IMPORTANT:

^ JIS batteries have different testing specifications than CCA batteries.

^ If you must use the GR-8 Battery Tester in a mode other than MODEL mode, JIS Mode MUST ALWAYS BE USED for JIS batteries otherwise an

incorrect result will occur. NEVER test a JIS battery using the CCA test in the GR-8; the test software in the GR-8 is different for JIS and CCA
modes. ANY CCA value you may have for a JIS-type battery is inaccurate for testing purposes.

^ ALWAYS test with the GR-8 using the MODEL mode (if available).

^ Selecting MODEL and vehicle type will automatically select the proper JIS or CCA value for the Original Equipment battery.

^ If the applicable vehicle is not listed, update the GR-8 to make sure it has the most recent data package. (1)

(1) To run the Midtronics Update Wizard for the GR-8 tester in CONSULT III:

^ Make sure the cables from the GR-8 to the multitasker are connected and both units are turned on.

^ Click on the ASIST icon.

^ Click on INFO. Tool Box.

^ Select Midtronics GR-8.

^ Midtronics Update Wizard file screen displays.

^ Click on Change MUP File.

^ The Select a MUP file window displays with the path: C:\ProgramFiles\Midtronics\MUW.

^ Select 192-725C and click OK.

^ Click on next and follow the prompts on the Midtronics Update Wizard screen.

If the applicable vehicle still is not listed:

1) Determine which type of battery (CCA or JIS) is installed in the vehicle. See below for descriptions of each battery.

2) Select CCA or JIS in the GR-8 based on the type of battery installed. See below for more information.

Determine the Battery Type

Batteries with JIS (Japanese Industrial Standard) Number

Electrical - Starting/Charging/Battery Testing|Page 2419 > < Electrical - Starting/Charging/Battery Testing