1.

Remove air and vacuum hoses from diverter valve. On some models, the air hose is clamped to a fitting on the diverter valve.

2.

Remove valve attaching screws, then the valve.

3.

Remove gasket material from valve and mounting surface.

4.

Reverse procedure to install, using a new gasket. Torque attaching screws to 125 inch lbs.