Page 14
background image

Note:  Apply LOCTITE(TM) Blue, GM P/N 12345382 (Canadian P/N 10953489) or equivalent to the bracket nuts (2).

54. Install the nuts (2) that attach the hydraulic pump bracket to the floor pan.

Tighten the nuts to 18 Nm (13 lb ft).

55. Connect the electrical connectors to the folding top control module, motor, solenoids and to the pump bracket.
56. Remove the protective covering.
57. Tighten the hydraulic pump bypass valve. Refer to Folding Top Pump Bypass Valve Pressure Release Adjustment   (See: Convertible Top

Pump/Adjustments).

58. Connect the battery. Refer to Battery Negative Cable Disconnection and Connection   (See: Starting and Charging/Battery/Battery Cable/Service

and Repair).

59. Inspect the hydraulic system fluid level and add fluid as needed. Refer to Folding Top Fluid Addition   (See: Convertible Top Hydraulic

Fluid/Service and Repair).

60. Connect a test kit J 35616   jumper switch to the actuator assembly folding top stowage compartment switch wiring harness (1) located behind the

right rear trim panel next to the folding top hydraulic pump.

Convertible Top Hydraulic Hose|Service and Repair|Page 11991 > < Convertible Top Hydraulic Hose|Service and Repair|Page 11989