Hose/Line HVAC: Service and Repair
Air Conditioning Condenser and Air Conditioning Evaporator Tube Replacement

Air Conditioning Condenser and Air Conditioning Evaporator Tube Replacement

Special Tools

J 39400-A  Halogen Leak Detector

Removal Procedure

1. Recover the refrigerant. Refer to Refrigerant Recovery and Recharging   (See: Service and Repair/Procedures/Refrigerant Recovery and

Recharging).

2. Remove the refrigerant pressure sensor wire harness connector.
3. Remove the refrigerant pressure sensor.

4. Remove the liquid line bracket bolt.
5. Remove the air cleaner assembly. Refer to Air Cleaner Assembly Replacement (NU6)   (See: Engine, Cooling and Exhaust/Engine/Tune-up and

Engine Performance Checks/Air Cleaner Housing/Service and Repair)Air Cleaner Assembly Replacement (NT7)   (See: Engine, Cooling and
Exhaust/Engine/Tune-up and Engine Performance Checks/Air Cleaner Housing/Service and Repair).

6. Remove the surge tank from the surge tank bracket.
7. Remove the suction hose and liquid line nut from the thermal expansion valve (TXV).
8. Remove the suction hose and liquid line from the TXV.