G8 V8-6.0L (2009)
16. Cap or plug the suction pipe upper (1) and the suction pipe lower (2).
17. Detach the suction pipe (2) and the liquid pipe (3) from the suction pipe/liquid pipe retaining clip (1).
18. Remove the suction pipe/liquid pipe pad to TX Valve retaining nut (1).
19. Disconnect the suction pipe/liquid pipe pad (3) from the TX valve (1).
Note: The sealing washers (2) are a single use item and must be discarded after use.
20. Remove the sealing washers (2). Refer to Sealing Washer Replacement (See: Coupler HVAC/A/C Coupler O-ring/Service and Repair/Sealing