pontiac Workshop Repair Guides

Pontiac Workshop Service and Repair Manuals

Air Door, HVAC > < Accumulator HVAC|Service and Repair
Page 2
background image

IMPORTANT:  Add the required amount of new refrigerant oil. Refer to Refrigerant System Capacities.

3. Install the refrigerant lines to the accumulator. Use the O-ring seals.

Tighten
Tighten the accumulator tube to accumulator and compressor tube to accumulator fitting nuts to 35 N.m (26 lb ft).

4. Install the cruise control bracket.
5. Evacuate and recharge the A/C system. Refer to Refrigerant Recovery and Recharging.
6. Leak test the fittings of the component using the J 39400-A.

Air Door, HVAC > < Accumulator HVAC|Service and Repair