porsche Workshop Repair Guides

Porsche Workshop Service and Repair Manuals

Installing and Removing Fresh/Recirculation Air Servo Motor|Page 4350 > < Installing and Removing Fresh/Recirculation Air Servo Motor|Page 4348
Page 2
background image

3. Release and unplug electric connector -a-.

4. Turn the servo motor out until the actuating lever -A- can be disengaged.
5. Remove servo motor.

Installing servo motor for temperature mixing flap

1. Position servo motor and engage actuating lever -A- on the servo motor.

2. Connect electric connector to servo motor until the connector is felt to engage.
3. Position servo motor on heater/air-conditioning unit and tighten with the three fastening screws -1-. - Tightening torque: 1.2 Nm (1.0 ftlb.)±0.5

Nm (±0.5 ftlb.)
3.1. First screw in one fastening screw.

3.2. Turn the servo motor and screw in the remaining two fastening screws.

Installing and Removing Fresh/Recirculation Air Servo Motor|Page 4350 > < Installing and Removing Fresh/Recirculation Air Servo Motor|Page 4348