CHECKING CHARGING SYSTEM

Note 1: 

Checking voltage between battery and alternator.

-

Start engine and idle. Turn on headlight, rear window defroster and heater blowers.

-

Connect voltmeter on terminal 30 of starter and battery + pole. If a voltage greater than 0.3V-0.4V is measured, check cables and grounding for the 
alternator and the battery.

-

The same measurement must be done between the alternator housing (B-) and the battery minus pole.