porsche Workshop Repair Guides

Porsche 911 Carrera 4 Cabriolet Workshop Manuals and Service Repair Guides

Diagnosis of Oxygen Sensing System Mixture Adaptation|Page 2919 > < Diagnosis of Oxygen Sensing System Mixture Adaptation|Page 2917
Page 2
background image

Oxygen Sensor Heater Monitoring

For proper function of the 02-sensor, the sensor element must be heated. A none functioning heater delays the sensor's readiness for closed loop control
and thus influences emissions.

The monitoring function measures both, the sensor heater current (voltage drop across a shunt) and the heater voltage (heater supply voltage) to calculate
the sensor-heater resistance.

The monitoring function is activated continuously, if the heater has been stabilized, and the current falls to a static value

Therefore the resistance of the 02-sensor heaters, with the help of a shunt both before and after the catalyst are measured and an additional right/left
diagnosis is realized.

Circuitry for heater controlling and heater current measuring

characteristics: