Oxygen Sensor: Description and Operation
Oxygen Sensor Monitoring

Oxygen Sensor Monitoring

The oxygen sensors are monitored for:

-

Operational readiness

-

Connectivity

-

Short circuit to B+

-

Short circuit to ECM ground

-

Open circuit

-

Aging of oxygen sensors via the control frequency and control position

Function of oxygen sensor diagnosis

General

To diagnose the oxygen sensor signals, the DME control module uses the form and frequency of the respective signal as a measuring value.

The data to be calculated for the DME control module are:

-

Time of sensor voltage between positive and negative edges

-

Maximum recognized sensor voltage value

-

Minimum recognized sensor voltage value

-

Oxygen sensor value towards rich

-

Oxygen sensor value towards lean

-

Sensing limits of oxygen sensing system

-

Period duration of sensors ahead of TWC

-

Sensor voltage ahead of TWC

Function

1. Determination of maximum and minimum sensor voltage

After starting the engine, the values for the previous maximum and minimum are erased. When driving, the absolute minimum and maximum are
formed in an engine speed and load range predetermined for diagnosis. These values are recorded by the ECM memory. If the sensor voltage is
higher than the presently stored maximum value, it will be overridden by the current sensor voltage. The same applies to the minimum value.

2. Calculation of time between positive and negative edges

If the sensor voltage exceeds the sensing limits, the measurement of the time between the positive and negative edges of the sensor signal is
started. If the sensor voltage is lower than the sensing limit, the time counter is stopped. The time between the starting and stopping of the counter
is measured.

Monitoring of Sensor Aging

Contamination or aging of the oxygen sensor affects the sensor voltage or period duration of the sensor signal and therefore has a negative influence on
emission values.

Illustration of the effect of period duration on emission values.