Page 4
background image

4    

Remove drive belt    
Slacken belt by turning the tensioning pulley (wrench size 24 mm) clockwise, hold still and simultaneously take the belt off the drive pulleys and
set aside.

5    

Remove catalytic converter of cylinder bank 1 - 3    
Undo the catalytic converter of cylinder bank 1 - 3 at the exhaust manifold. Unplug oxygen sensor cable and unclip. Remove the holding clamp
between the catalytic converter and support sheet and undo the two exhaust clamps. Take catalytic converter off of the exhaust manifold, pull out
of end muffler.

6    

Secure catalytic converter    
Turn the catalytic converter and tie in place as shown in the illustration. Cover body to protect from damage.