Undervoltage '[<]  9 V'.

-

Overvoltage '[>] 16 V'.

Frequency counter

When a fault first occurs, a fault entry with the status 'present' is set in the fault memory and the counter is
simultaneously set to '50'. If a fault is present, the counter is incremented by one whenever the system is 'booted'.
The maximum count is 255.
The counter is decremented if the status 'fault no longer present' is entered and the fault does not occur again when
the system is 'booted'. The entry in the fault memory is erased automatically when the counter reaches 0. If the
error occurs again when the counter is between 1 and 49, the counter is reset to 50.

Temperature:

The value indicates the temperature (temperature sensor in the gateway) at the time the fault occurred. The
temperature of the fibre optic transmitter is monitored: max 85°C.

Voltage

The value indicates the voltage at the time the fault occurred.

Vehicle speed:

The value indicates the vehicle speed at the time the fault occurred.

Display '*' in the menu 'Control modules' and menu 'PCM2/CDR23 MOST component check'.

Different required and actual installed components lists

When the 'automatic control module search' is complete, the following display'*' appears in front of the control module description 'PCM2' in the
'Control modules' menu, as well as in the 'PCM2 MMI function selection' in front of the entry 'MOST required installed components list' if the9588
Porsche System Tester II establishes a difference between the required and actual installed components list and there is no fault code in one of the fault
memories of the MOST control modules.

If there is a fault code present in one of the MOST control modules, the display '*' is only shown in the 'PCM2 MMI function selection' in front of the
line 'MOST required installed components list'.

If there is a display in the menu Control module, an existing fault code has priority and a '#' is set.

Most Switch

MOST switch

The MOST switch is part of the PCM2. If external MOST control modules are present, they will only work if the MOST switch is open.

The following settings can be coded:

-

MOST switch open.

-

MOST switch closed.

NOTE:
-

When the PCM2 is replaced, the coding must be performed in accordance with the vehicle equipment.

-

When the 'Switch closed' parameter is set, the switch remains closed even in existing MOST control modules. Communication is then not possible.

Production Mode

Production mode

If the MOST control module is set to Production mode on, it is in low-current mode. This status is indicated by the message 'PROTECTED' on the
display. The control module cannot function. If production mode is coded out, the control module is operational again following a restart (vehicle must
be locked and secured).

The following options can be coded:

-

Production mode off.

-

Production mode on.

Country-Specific Tuner Settings

Country-specific tuner settings

The following country-specific tuner settings can be coded:

-

Europe.

-

North America.