porsche Workshop Repair Guides

Porsche Workshop Service and Repair Manuals

Removal and Replacement|Page 1410 > < Removal and Replacement
Page 2
background image

Cover for magnetic hydraulic valves in installation position with integrated seal

7. The cap of the stabilizer mount must be removed before the lower hexagon-head bolt -2- (Item 12 in the tightening sequence diagram) can be

unscrewed. Unscrew the two M8 hexagon-head bolts -1- for this purpose.

Caution
When levering off the cylinder head cover, the cast lugs may break!

8. Remove the cylinder head cover. To do this, unscrew 20 M6 x 30 hexagon-head bolts from the cylinder head cover. Unscrew the two M6 x 20

hexagon-head bolts on the sides of the oil extraction pump. To release the cylinder head cover, raise the cover carefully at the two protruding cast
edges with a slotted screwdriver. Remove the cylinder head cover of bank 1-3.

Figure shows upper cast lug.

Installing cylinder head cover - cylinder bank 1 - 3

Information
 -

The sealing surfaces of the cylinder heads and the cylinder head covers must be cleaned before the new sealant is applied. Avoid damage!

1. Clean sealing surfaces. Remove any sealant residue from the sealing surfaces on the cylinder head and the cylinder head cover thoroughly. Then

rub down with a clean cloth soaked in a degreasing agent (e.g. acetone, solvent naphtha). Make sure that no sealant residue can enter the cylinder
head.

2. Replace the 3 seals for the spark-plug recesses.

Only the following sealants may be used to seal the cylinder head cover:

 -

Drei Bond Silikon - type 1209 (beige)

Removal and Replacement|Page 1410 > < Removal and Replacement