Catalytic Converter: Description and Operation

Monitoring the efficiency of the Three Way Catalytic Converter (TWC) 

In this process the oxygen storage capacity of the TWC is determined by comparing the oxygen sensor amplitudes ahead and after the TWC. If the
oxygen storage capacity is diminished through aging of the TWC, the oxygen sensors after the TWC also show voltage amplitudes. The amplitude of
the oxygen sensor ahead of the TWC is used as the target value and is therefore determined through the same signal path.

The quotient of the rear and front amplitude, the amplitude ratio, is used as the measuring value. The appearance of amplitudes after the TWC is
dependent on the momentary load of the storage capacity of the TWC. This load can vary from load to rpm, which is why a load and rpm-dependent
evaluation (tl/n) is done.

TWC is OK

A:  Sensor amplitude ahead of TWC
B:  Sensor amplitude after TWC TWC is OK.

TWC is NOT OK

A:  Sensor amplitude ahead of TWC
B:  Sensor amplitude after TWC, TWC not OK
X:  Delay due to gas running time:

NOTE:  The comparison of both sensor voltages is the measurement for the efficiency of the Three Way Catalytic Converter

Oxygen sensor monitoring 

The monitoring of the oxygen sensors was increased with OBD II.

The oxygen sensors are monitored for:

Operational readiness.

Connectivity.

Short circuit to positive.

Short circuit to ECM ground.

Wire break.

Aging of oxygen sensors via the adjustment frequency and adjustment position.