porsche Workshop Repair Guides

Porsche Workshop Service and Repair Manuals

Dashboard / Instrument Panel > < Instrument Panel, Gauges and Warning Indicators|Service and Repair|Page 4997
Page 4
background image

1. Connect the Porsche System tester to the vehicle and start the System tester. Switch on ignition. >> Continue.
2. Select the vehicle type.
3. Switch from the vehicle type to the list of control units.
4. Select Stopwatch with the cursor keys and press the >> key.
5. Select Control unit replacement with the cursor keys and press the >> key.
6. Select Read out values (codings) with the cursor keys and press >>.
7. The message Codes successfully read out appears on the screen of the Porsche System tester. Press >>.
8. Switch off ignition and replace control unit.
9. Switch on ignition, switch to the Special functions menu and perform the Vehicle handover using the F8 key.

10. In the Special functions menu, erase All fault memories by pressing >>.
11. Carry out automatic search of control units.
12. In the menu Write in data >>, the data read-out is installed.
13. System tester displays Coding write-in complete >>.
14. Quit menu, check operation of stopwatch and read out fault memory.

Coding stopwatch

WARNING:
Sudden voltage interruption of the power supply to the control module.
-

Destruction of the control module.
-

During programming, it is essential to guarantee the power supply for the Porsche System tester. It is essential to connect a battery
charger with a current rating of at least 40 A to the vehicle battery.

-

Prior to disconnecting the control module, switch off the ignition and remove the ignition key.

INFORMATION:
-

The PIWIS Tester 9718 instructions take precedence since the description may be different. This may be due to more recent software versions.

-

The procedure described here has been structured in general terms; different text or additions may appear in the PIWIS Tester 9718.

-

The procedure described must be applied when a control unit has to be replaced and the tester function Control unit replacement cannot be used.

1. Connect the PIWIS tester 9718 to the vehicle and start it. Switch on the ignition. >> Continue.
2. Select the vehicle type.
3. Switch to the Special functions menu and perform the vehicle handover using the F8 key.
4. In the Special functions menu, erase All fault memories by pressing >>.
5. Carry out automatic search of control units.
6. Using the >> key, move from the vehicle type to the list of control units.
7. Select Stopwatch with the cursor keys and press the >>.

INFORMATION:  The codings will be optimized with later versions of the tester software; the coding scope documented here serves as a guide.

8. Select Stopwatch with the cursor keys and press the >>.

Illumination settings:

Default
Illumination off

Time constant brighter

Reference value >> 3.2

Time constant darker

Reference value >> 12.8

9. Quit menu, check operation of stopwatch and read out fault memory.

Dashboard / Instrument Panel > < Instrument Panel, Gauges and Warning Indicators|Service and Repair|Page 4997