porsche Workshop Repair Guides

Porsche Workshop Service and Repair Manuals

Initial Inspection and Diagnostic Overview|Page 37 > < Initial Inspection and Diagnostic Overview
Page 1
background image

General Module: Component Tests and General Diagnostics

PCM2 Gateway - Introduction

Gateway - Introduction

The manual contains the diagnosis for the following system:
PCM2 gateway

General Instructions/Safety Instructions

The following points must be observed during vehicle diagnosis:

-

After the battery is connected, volatile memories must be reprogrammed. In the case of radio coding and tuning, the customer must be informed of
decoding and the deleted tuner memory.

-

Deactivate the 'automatic traffic announcement' before beginning the diagnosis on the PCM2. If this is not done, the system will crash.

-

When working on the optical waveguides, please observe the instructions in assembly;  refer Optical waveguide - MOST bus.

-

After troubleshooting or repairs, erase the fault memory with the Porsche System Tester II No. 9588 and carry out a test drive.

-

Nach der Probefahrt erneut Fehlerspeicher mit Porsche System Tester II No. 9588 auslesen.

DANGER:

Danger of injury through triggering of driver's airbag

-

Never hang the Porsche System Tester II No. 9588 over the steering wheel.

CAUTION:

Danger of damage due to improper handling of the battery and the control unit connectors.

-

Never disconnect battery with engine running.

-

Never start engine without securely connected battery.

-

Never pull off or push on plug connections for the control modules or other electronic components when the ignition is switched on.

General Information On The Fault Memory

Fault Code setting conditions

Fault Codes can be set in several circumstances, e.g.:

-

battery disconnected

-

plug connections disconnected

-

power failure

In these circumstances, no fault is present in the system and the fault memory must be erased.

Fault memory Info key [F8]

In order to be able to assess the fault exactly, the fault memory Info key F8 must be pressed. This information should be saved using the Save key F4 and
printed out. If a fault code is stored with "not present" status and no other problems are present, then the fault memory must be erased.

Fault type - Frequency counter/Temperature/Voltage;  Speed/Time of occurence

Supply voltage fault type

The display shows which fault type has occurred:
-

Undervoltage '< 9 V'

-

Overvoltage '> 16 V'

Frequency counter

When a fault first occurs, a fault entry is made in the fault memory and the counter is simultaneously set to 50.
If a fault is present, the counter is incremented by 1 for each "ignition on". The maximum count is 255.
The counter is decremented if the fault is no longer present. The fault memory is automatically erased when the counter
reaches 0.
If the error occurs again when the counter is between 1 and 49, the counter is reset to 50.

Temperature:

The value indicates the temperature (temperature sensor in the gateway) at the time the fault occurred. The temperature of
the fibre optic transmitter is monitored:  max 85 degree C.

Voltage

The value indicates the voltage at the time the fault occurred.

Initial Inspection and Diagnostic Overview|Page 37 > < Initial Inspection and Diagnostic Overview