Cayenne GTS (9PA) V8-4.8L (2008)
2.1. Clip in holder for magnetic-field sensor and electric line on bracket for seat-belt buckle.
3. Fasten bracket for seat-belt buckle.
3.1. Position bracket for seat-belt buckle and screw down with three new fastening screws -1- - Tightening torque: 37 ftlb.
4. Calibrate magnetic-field sensor.
Installing magnetic field sensor - USA version as of model year 2005
1. Install magnetic field sensor.
1.1. Insert magnetic-field sensor in the holder and press down until the two locking tabs are felt to engage.
2. Plug in connector and fasten holder for magnetic-field sensor.
2.1. Swivel holder for magnetic-field sensor to the front and screw down with the two fastening screws -2- - Tightening torque: 4.5 ftlb.
2.2. Push connector onto magnetic-field sensor until the connector is felt to engage.
3. Calibrate magnetic-field sensor.
Calibrating magnetic field sensor
INFORMATION:
-
After replacing the magnetic-field sensor, a calibration must be performed.
-
In the multi-function display the warning CAL appears.
-
To calibrate the compass follow the instructions of the multi-function display.
1. On the instruction DRIVE A FULL CIRCLE, the vehicle will need to be driven round the block on the street, for example, to calibrate the
magnetic-field sensor.