Page 6
background image

23. Tie together the wire harness with insulating tape and route it so that the crimps -1- can be positioned on the firewall in the area above the foam

grommet -2- in stages.

24. Attach new tie-wrap -1- to Porsche Stability Management control unit connector.
25. Mount cap on Porsche Stability Management control unit connector until this is felt to engage.

26. Attach armouring to wire harness from Porsche Stability Management control unit connector up to foam grommet -1- in the firewall and fit

corrugating hoses.

27. Mount the Porsche Stability Management control unit connector and lock -arrow A-.
28. Insert wire harness in the three retaining clips and close -arrow B-.

29. Route wire harness -1- under the hydraulic unit.