1. Plug in the outer connector -2- ( -arrow A- ) until the locking lugs engage securely -arrows B-.
2. Plug in the inner connector -1- ( -arrow C- ) until the locking lug -arrow D- engages securely.
INFORMATION: Before connecting the water hoses, apply suitable rubber lubricant to the flanges.
3. Connect the housing to the inner water hose -2- ( -arrow A- ).
4. Screw down the housing on the holder using the fastening screws -arrows 3-. - Tightening torque: 8 Nm (6 ftlb.)
5. Push the moulded hose onto the housing -arrow B-.
6. Align the moulded hose without tension by turning it back and forth -arrows A-.
7. Push the spring band clamp onto the connection using the assembly pliers for spring band clamps, Cayenne hose connections NR.72-1 -a- ( -arrow
B- ).
8. Relieve spring band clamp -arrows C- and secure the hose.
9. Align the hose without tension by turning it back and forth -arrows A-.
10. Push the spring band clamp onto the connection using the assembly pliers for spring band clamps, Cayenne hose connections NR.72-1 -a- ( -arrow
B- ).