17. Fit hose connection from charge air cooler. The connection piece must engage audibly. Ensure that the locking spring -1- is fitted correctly.

Work steps for blocked/seized up air conditioning compressor

1. Remove desiccator from the condenser.
2. Check the desiccator for wear/chips.

If there is wear/chips:

3. Remove the refrigerant line between the compressor and condenser.
4. Replace the refrigerant line between the compressor and condenser.
5. Replace the condenser with desiccator.
6. Install the new refrigerant line between the compressor and condenser.

If there is no wear/chips:
-

Replace the desiccator.

Subsequent work

1. Install drive belt.
2. Install engine guard.
3. Install left air cleaner housing.
4. Install left wheel housing liner.
5. Fit front left wheel.
6. Fill refrigerant on the air conditioner in accordance with regulations.
7. Open air exhaust nozzles on the dashboard, and set fan to at least 75 %.
8. After allowing the system to stabilise at idle speed (approx. 5 sec.), switch on air conditioning and allow the engine to run uninterrupted for at least

2 minutes at an engine speed of less than - Engine speed: 1500 rpm.

9. Switch off the air conditioner again. Do not drive until the air conditioner has been filled.

10. Park the vehicle in an open area and bleed Porsche Dynamic Chassis Control (PDCC).

Condenser HVAC > < Diagram Information and Instructions|Page 4938