Cayenne Turbo (9PA) V8-4.8L Turbo (2008)
1. Open the secondary locking mechanism using the press-out and unlocking tools for tab and round plug connectors of all sizes NR.155. Insert the
tool in the opening provided and lift the locking mechanism. The locking mechanism engages in the upper position.
2. Position the press-out and unlocking tools for tab and round plug connectors of all sizes NR.155 on the primary locking mechanism and lift the
locking mechanism.
3. Carefully pull on the optical waveguide -A and B- in -direction of arrow-. If it is not possible to pull out the optical waveguide, check again if the
secondary locking mechanism is completely released and if the primary locking mechanism is raised sufficiently.
Perform visual inspection of locking mechanisms, connector housings and contacts for possible damage, and exchange the damaged parts, if
necessary.
Installing Optical Contacts On Connector Side
Remove the dust boot right before plugging.
Check the proper condition of the contacts.
1. Insert the optical contact -A and B- in the connector until it engages audibly.