Cayman (987) F6-2.9L (2009)
1. Release the spring cap on both sides using the press-out and unlocking tools for tab and round plug connectors of all sizes NR.155 and remove it.
2. Remove optical waveguide module from connector.
3. Position the press-out and unlocking tools for flat-type and round plug connectors of all sizes NR.155 for releasing the contact locking mechanism
of the optical waveguide module and lift up the locking mechanism.
4. Carefully pull on the optical waveguide -A and B- in -direction of arrow-. If it is not possible to pull out the optical waveguide, check again if the
locking mechanism is completely released.