Oxygen Sensor: Description and Operation
Part 1

Oxygen Sensor Monitoring

General Description

The Lambda control consists of a linear Oxygen sensor (LSU) upstream catalyst and one Oxygen sensor downstream front catalyst and post main
catalyst. The control loops downstream catalysts correct deviations of the upstream oxygen sensor (LSU).

All sensors are monitored by several single monitoring procedures under the following basic conditions.

The following checks will be performed on the linear oxygen sensor (LSU) upstream catalyst:

Plausibility Check

Any deviation from the characteristic curve of oxygen sensor upstream catalyst due to poison, ceramic cracks, characteristic shift down (CSD) or a
leakage will be detected. The diagnostic function monitors the integral component of the fuel trim controller, which when filtered over time represents an
offset in the characteristic curve of the primary oxygen sensor - see Figure 1. The offset of this characteristic curve is itself determined by deviations in
trim control and the set point value of the downstream lambda controller.

An unacceptable shift in the primary oxygen sensor's characteristic curve indicates either a fuel trim fault or a faulty primary oxygen sensor.

General monitoring conditions

All of the following monitoring conditions must be satisfied for all checks:

-

the secondary oxygen sensor diagnosis has been performed and no malfunctions were detected

-

the secondary oxygen sensor's power stage diagnosis has been performed and no malfunction was detected

-

the voltage diagnosis of the primary oxygen sensor has been performed and no faults where detected

-

the exchanged secondary oxygen sensors check (e.g. bank 1's secondary sensor mistakenly mounted in bank 2) has been performed and no faults
was detected

-

the aging diagnosis of the secondary oxygen sensor has been performed and no malfunctions were detected

-

the oscillation check of the secondary oxygen sensor has been performed and no malfunction was detected.

Fuel trim faults