porsche Workshop Repair Guides

Porsche Workshop Service and Repair Manuals

Restraints - Air Bag Lamp ON/Various DTC's Set|Page 3657 > < Restraints - Air Bag Lamp ON/Various DTC's Set|Page 3655
Page 4
background image

airbag - Coding

Subsequent work

Subsequent work for triggering unit

1. If installed, install control unit for tilt sensor. Refer to Removing and installing control unit for tilt sensor.
2. Connect battery. Refer to Work instructions after disconnecting the battery.
3. Install centre console. Refer to Removing and installing centre console.
4. Install centre console cover. Refer to Removing and installing centre console cover.
5. Install left and right covers of console. Refer to Removing and installing centre console cover.

Programming triggering unit

Triggering unit - reading out and writing in data

WARNING:  Sudden voltage interruption of the power supply to the control module.

-

Destruction of the control module.
-

During programming, it is essential to guarantee the power supply for the Porsche System tester. It is essential to connect a battery charger
with a current rating of at least 40 A to the vehicle battery.

-

Prior to disconnecting the control module, switch off the ignition and remove the ignition key.

1. Connect the Porsche System Tester to the vehicle and start the System Tester. Switch on ignition. >> Continue.
2. Select vehicle type using the cursor keys.
3. Move from vehicle type to the list of control units. Locking is only possible after an automatic control unit search.
4. Select Posip with the cursor keys and press the >> key.
5. Select Control unit replacement with the cursor keys and press the >> key.
6. Select Read out values (codings) with the cursor keys and press >>.
7. The message Codes successfully read out appears on the screen of the Porsche System Tester. Press >>.
8. Switch off ignition and replace control unit.
9. Switch on ignition. Switch to the Special functions menu and perform the vehicle handover using the F8 key.

10. In the Special functions menu, erase All fault memories >>, compare Vehicle identification number and confirm.
11. With the cursor keys on Posip - Replacing control unit, after replacement of the control unit, the readout data (see Section 6) are installed under

the menu Write in data press >>.

12. System Tester displays Codes successfully written in. Press >>.
13. Locking is only possible after an automatic control unit search.

Lock triggering unit:

14. Change to the menu Posip - lock and press >>.
15. Select the country-specific Equipment and press >>.
16. Start Lock with F8.
17. Observe message on Tester.
18. Quit menu, carry out a test drive, and read out fault memory.

Coding triggering unit

WARNING:  Sudden voltage interruption of the power supply to the control module.

-

Destruction of the control module.
-

During programming, it is essential to guarantee the power supply for the Porsche System tester. It is essential to connect a battery charger
with a current rating of at least 40 A to the vehicle battery.

-

Prior to disconnecting the control module, switch off the ignition and remove the ignition key.

INFORMATION:  The procedure described must be applied when a control unit has to be replaced and the tester function Control unit replacement
cannot be used.

1. Connect the PIWIS tester 9718 to the vehicle and start it. Switch on the ignition. >> Continue.
2. Switch to the Special functions menu and perform the vehicle handover using the F8 key.
3. In the Special functions menu, erase All fault memories >>, compare Vehicle identification number and confirm.
4. Select vehicle type using the cursor keys.
5. Using the >>, move from the vehicle type to the list of control units. Locking is only possible after an automatic control unit search.
6. Select Posip with the cursor keys and press >>.
7. Select Coding and press the >>.
8. Select Thorax driver and code with F8.

Restraints - Air Bag Lamp ON/Various DTC's Set|Page 3657 > < Restraints - Air Bag Lamp ON/Various DTC's Set|Page 3655