Panamera S (970) V8-4.8L (2010)
Fuse Block: Testing and Inspection
Eliminating Symptoms In Body Interior: Replacing Power Distributor (main Fuse Box) (error Message/warning Light Activated In Instrument
Cluster/SY2309)
General information
Symptom
The following possible errors can occur together:
Text message in instrument cluster:
-
Ignition lock faulty
-
PSM fault
-
System fault
-
Reduced engine power
-
Start/Stop deactivated
-
Transmission fault
and/or warning light in instrument cluster:
-
Check Engine
-
ABS fault
-
Brake
-
Hold function
Cause, date of introduction and remedial action
Cause
A blade contact in the terminal 15 relay socket in the power distributor (main fuse box) may be damaged as a result of incorrect assembly.
Date of introduction
Power distributors that were checked and found to be OK are installed in vehicles as of the following vehicle identification numbers: