Alarm Module: Description and Operation
ECM Power Supply and Gnd, Anti-Theft Alarm

Electronic Control Module Power Supply

-

The +30 power supply goes direct to pin 25 of the control module. There is no fuse in this circuit. (In certain markets the +30 power supply goes
via fuse 19).

-

The +15 power supply goes direct from distribution terminal 159 to pin 10 of the control module. There is no fuse in this circuit.

-

The +50 power supply goes to pin 20.

Electronic control module ground

Electronic control module main ground (pin 13) is connected to grounding point G6.