saturn Workshop Repair Guides

Saturn Workshop Service and Repair Manuals

Mechanical Specifications|Page 11326 > < Mechanical Specifications|Page 11324
Page 2
background image

5. Rotate locking tabs outward to release filter assembly.
6. Remove filter by lifting straight up.

7. Remove filter housing attachment bolts and remove filter housing.

8. Remove blower motor housing screws, release locking tabs and remove housing.
9. Disconnect blower motor electrical connector by squeezing bottom of connector and pulling downward.

10. Remove blower motor assembly by lifting straight out.

IMPORTANT:  Verifying the purity of the refrigerant with a purity identifier before recovery is recommended.