saturn Workshop Repair Guides

Saturn Workshop Service and Repair Manuals

Mechanical Specifications|Page 11327 > < Mechanical Specifications|Page 11325
Page 3
background image

11. Recover refrigerant using an approved refrigerant recovery system. Measure the amount of oil lost during recovery and record.

NOTE:  When removing the TXV, keep dirt and foreign material from getting on or into the O-ring sealing surfaces. Clean tools and a clean
work area are important for proper service. The TXV seal area should be cleaned before any repairs are begun. The parts must be kept clean
at all times and any parts to be assembled should be cleaned with a non-petroleum based solvent and dried with air. Use only lint free cloths
to wipe parts. Do not allow solvent to enter evaporator or hoses.

CAUTION:  DO NOT REMOVE HOSES OR LINES BEFORE SYSTEM IS FULLY DISCHARGED.

12. Remove suction/liquid line assembly to TXV retaining bolt.

13. Remove suction/liquid line assembly block from TXV by gently rocking while pulling forward.
14. Install cap on suction/liquid line hose assembly to prevent oil spillage.
15. Remove TXV retaining bolts.

Mechanical Specifications|Page 11327 > < Mechanical Specifications|Page 11325