SW1 L4-1.9L SOHC VIN 8 (1996)
^
If using Cooling Coil Coating (P/N 12346390), safety glasses
^
Rubber gloves
^
Pedestal fan Plug (P/N 21121827)
1.
Dry evaporator by:
^
Adjusting temperature to lull hot
^
Turning RECIRC On
^
Making sure A/C button is Off
^
Close all doors and windows
^
Start engine and allow to reach operating temperature
^
Allow blower motor to operate on HI blower for 5 minutes, once engine reaches operating temperature
2.
Raise vehicle on a hoist.
3.
Check the HVAC module drain for blockage. If necessary, clear drain hole with a soft blunt tool such as the eraser end of a pencil.
4.
Lower vehicle from hoist.