saturn Workshop Repair Guides

Saturn Workshop Service and Repair Manuals

A/C - Odors at Vehicle Start Up|Page 8073 > < A/C - Odors at Vehicle Start Up|Page 8071
Page 5
background image

13.

Using a 15/32 in. drill bit, attach a drill stop. or depth gauge, or masking tape to allow for a 4 mm (5/32 in.) depth.

14.

Locate the center of the triangle shaped portion of the plenum which slopes upward and to the right, next to the left-most blower motor fastener.

NOTICE:

Running the drill bit in more than 4 mm (5/32 in.) can damage the evaporator.

15.

Drill a 15/32 in. hole. Be careful not to let the drill bit penetrate beyond a 4 mm (5/32 in.) depth.

IMPORTANT:

Depending on part availability, two different products may be available for use on A/C evaporators. Select the appropriate procedure to follow based
on the product you will be using:

^

If using the Disinfectant Kit (P/N 21030784; P/N 10953503 for Canada), continue to the "Evaporator Disinfecting Using Disinfectant Kit (P/N
21030784; P/N 10953503 for Canada)" procedure in this bulletin.

^

If using the Cooling Coil Coating (P/N 12346390), continue to the "Applying Cooling Coil Coating (P/N 12346390) to Evaporator" procedure in this
bulletin.

Evapor. Disinfecting Using Disinfectant Kit

EVAPORATOR DISINFECTING USING
DISINFECTANT KIT (P/N 21030784; P/N
10953503 FOR CANADA)

Perform this procedure only if you are using A/C
System Disinfectant Kit (P/N 21030784; P/N
10953503 for Canada).

CAUTION

THIS PROCEDURE SHOULD ONLY BE PERFORMED ON A COLD CAR. IT HAS BEEN DEMONSTRATED THAT IRRITATING VAPORS
WILL BE FORMED IN THE ENGINE COMPARTMENT IF THE DISINFECTANT COMING OUT OF THE DRAIN OUTLET CONTACTS
HOT ENGINE COMPONENTS. DISINFECTANT CAN CAUSE SUBSTANTIAL, BUT TEMPORARY EYE INJURY. DO NOT GET
DISINFECTANT IN EYES OR ON CLOTHING. WASH THOROUGHLY WITH SOAP AND WATER AFTER HANDLING.

FIRST AID: IF DISINFECTANT GETS INTO EYES, HOLD EYELIDS OPEN AND FLUSH WITH A STEADY, GENTLE STREAM OF WATER
FOR 15 MINUTES. OBTAIN MEDICAL ATTENTION IF IRRITATION PERSISTS.

1.

Allow vehicle to cool down before performing disinfectant procedure.

2.

Put on rubber gloves, safety goggles and MOSH approved acid gas/organic vapor respirator.

3.

Pour the small bottle of the two part A/C System Disinfectant Kit (P/N 21030784; P/N 10953503 for Canada) into the large bottle. Put the cap
back on the large bottle and invert bottle once or twice to mix the contents.

4.

Using cleaning gun, OTC Tool SA9216NE (or equivalent siphon-type parts cleaning spray gun capable of delivering 2 ounces per minute of liquid
with shop air at 552-620 kpa [80-90 psi]), insert siphon hose into container of disinfectant. Take care to place the bottle in a secure upright
position to avoid spilling contents.

A/C - Odors at Vehicle Start Up|Page 8073 > < A/C - Odors at Vehicle Start Up|Page 8071