Expansion Valve: Service and Repair

REMOVAL

1. Recover refrigerant using an approved refrigerant recovery system.

CAUTION: Verifying the purity of the refrigerant with a refrigerant purity identifier before recovery is recommended.

WARNING: DO NOT REMOVE HOSES OR LINES BEFORE SYSTEM IS FULLY DISCHARGED.

2. Remove air cleaner cover and air induction hose at intake manifold.
3. Remove suction hose from Thermal Expansion Valve (TXV).
4. Remove liquid line from TXV.
5. Remove TXV from evaporator.