1.

Bias voltage of less than 600 mV should be observed with oxygen sensor disconnected. If higher voltage is observed, the source must be
diagnosed.

2.

Turning On cooling fans may provide the voltage source for oxygen sensor short.

3.

Oxygen sensor wire perforation results in short to voltage through conductive salt water. If harness was exposed to salt water in the past, wetting
the harness will "reactivate" the salt water short.

4.

If the voltage on oxygen sensor wire is less than 600 mV, refer to service manual for appropriate symptom diagnosis.

PARTS REQUIREMENTS:

21022282

Connector Kit-Oxygen Sensor (1 required)

21022987

Sensor Asm-Exhaust Oxygen (1, if required)

21020792

Strap-Wiring Harness (10 required)

21023494

Conduit-Wiring Harness (1.5 meters [5 ft.] required.)  

IMPORTANT: 

Conduit is packaged in a 3 meter (10 ft.) length package. One package is to be used for two vehicles.

12116140

0.80 sq. mm (18 gauge) stranded copper wire with GXL insulation (2.75 meters [9 ft.] required)

Crimp and Seal Splice (Salmon/Pink) 
OTC P/N 217670 (2 required)