SW2 L4-1.9L DOHC VIN 7 (1997)
NOTICE: Use only R-12 Refrigerant oil (mineral) to lubricate O-rings. Use of R-134a (PAG) oil will cause premature corrosion of fitting joints.
81. Lubricate O-rings with R-12 Refrigerant oil (mineral) and install new O-rings on suction hose and liquid line.
82. Install liquid line on TXV
Torque: 25 N.m (19 ft-lbs)
83. Install suction hose on TXV
Torque: 25 N.m (19 ft-lbs)
84. Install air cleaner housing cover and air induction hose.
85. Fill and pressure test the cooling system.
86. Evacuate, charge, and leak test A/C system. Perform A/C Performance Test.
87. Connect negative battery cable.
Torque: 17 N.m (151 in-lbs)
88. Set clock to proper time if equipped.
89. Enable the SIR system. (Refer to Enabling the SIR System in Service Precautions.)
90. Reset radio stations.