INSTALLATION PROCEDURE

1. Measure and cut the new TPS assembly to the proper length.

IMPORTANT:  To ensure proper routing and retention, be sure the new TPS assembly is cut to the same length as the original TPS assembly.

2. Remove 9.5 mm (3/8 in) of insulation from the ends of the TPS assembly and the wire harness.
3. Position the stripped ends of wire in the appropriate splice sleeve found in J 44020.
4. Crimp the splices using an approved crimping tool.
5. Gently tug on the wires to ensure proper crimping.

6. Apply heat to the splice joints until glue flows from the splice sleeves.