saturn Workshop Repair Guides

Saturn Workshop Service and Repair Manuals

A/C - Poor Performance/Erratic Operation|Page 8003 > < A/C - Poor Performance/Erratic Operation|Page 8001
Page 4
background image

4.

Connect the wire harness to the window switches, mirror switch and cigarette lighter.

5.

Install front edge of horseshoe bezel over shift assembly making sure to engage alignment pins, then snap bezel into place by pressing down.

6.

While applying the brake, return shifter to the "P" Park position.

Procedure:

Condition 2 - Reduced or no airflow from outlets and/or selected HVAC modes are inoperative with HVAC blower motor on.

For HVAC Controller Calibration, perform the following:

Important:

Any time an HVAC module mode actuator or HVAC controller is replaced, the HVAC controller will need to be calibrated to ensure proper air
distribution.

1.

Calibrate mode door by simultaneously pushing the A/C and Recirc buttons on the HVAC controller 3 time each within 2 seconds of the initial
push.

^

A/C and RECIRC button LEDs will flash while this calibration is taking place.

^

Calibration will take anywhere between 10 to 30 seconds depending on battery voltage.

^

LEDs will quit flashing when calibration is complete.

2.

Cycle ignition and verify proper operation of mode doors.

A/C - Poor Performance/Erratic Operation|Page 8003 > < A/C - Poor Performance/Erratic Operation|Page 8001