32. Now, check the generator control module for voltage potential, in order to ensure that the module has been disabled.

1. Measure from the 36-volt positive terminal (3) to vehicle chassis ground (2). The voltage should be less than 3 volts.
2. Measure from the 12-volt positive terminal (5) to vehicle chassis ground (2). The voltage should be less than 3 volts.
3. Measure from the negative terminal (4) to vehicle chassis ground (2). The voltage should be less than 3 volts.

Caution:  To help avoid personal injury, always treat the 3-phase cable and connectors as if voltage is present and as if the surface of all
parts of the cable is hot.

33. Verify that the generator control module 3-phase cables are disabled.

1. Measure from each phase 1, 2, and 3 connection (1) to ground (2). The voltage should be less than 3 volts.
2. After verifying that there is no voltage present, the generator control module 3-phase cables can now be removed from the generator control

module.

34. Partially raise and support the vehicle. Refer to Vehicle Lifting.
35. Remove the fuel injector wiring harness electrical connector retainer (6) from the generator starter tab.

Drive Motor Power Cable|Service and Repair|Page 4497 > < Drive Motor Power Cable|Service and Repair|Page 4495