xA L4-1.5L (1NZ-FE) (2006)
9. DISCONNECT LIQUID TUBE SUB-ASSEMBLY
a. Remove the bolt and liquid tube from the condenser.
b. Remove the O-ring from the liquid tube.
NOTE: Seal the opening of the disconnected parts using vinyl tape to prevent moisture and foreign matter from entering.
10. REMOVE CONDENSER WITH RECEIVER ASSEMBLY
a. Remove the 2 bolts and condenser.
INSTALLATION
1. INSTALL CONDENSER WITH RECEIVER ASSEMBLY
a. Install the condenser w/ receiver with the 2 bolts.
Torque: 9.8 N.m (100 kgf.cm, 7 ft.lbf)
2. CONNECT LIQUID TUBE SUB-ASSEMBLY
a. Remove the vinyl tape attached to the liquid tube and condenser.