REMOVAL

1. DISCONNECT CABLE FROM NEGATIVE BATTERY TERMINAL

CAUTION:  Wait at least 90 seconds after disconnecting the cable from the negative (-) battery terminal to prevent airbag and seat belt
pretensioner activation.

2. DISCHARGE REFRIGERANT FROM REFRIGERATION SYSTEM
3. REMOVE RADIATOR GRILLE
4. REMOVE LOW PITCHED HORN ASSEMBLY
5. REMOVE HIGH PITCHED HORN ASSEMBLY

6. REMOVE HOOD LOCK ASSEMBLY

a. Remove the 3 bolts and hood lock.

7. REMOVE HOOD LOCK SUPPORT SUB-ASSEMBLY

a. Remove the clip.
b. Remove the 2 bolts and hood lock support.

8. DISCONNECT NO. 1 COOLER REFRIGERANT DISCHARGE HOSE

a. Remove the bolt and disconnect the cooler refrigerant discharge hose from the condenser.
b. Remove the O-ring from the cooler refrigerant discharge hose.

NOTE:  Seal the opening of the disconnected parts using vinyl tape to prevent moisture and foreign matter from entering.