e. Disconnect the suction hose.

NOTE:
-

Do not use tools, such as a screwdriver, to remove the tube.

-

Cap the open fittings immediately to keep moisture or dirt out of the system.

f.

Remove the 2 O-rings from the suction hose.

NOTE:  Seal the openings of the disconnected parts using vinyl tape to prevent moisture and foreign matter from entering.

4. DISCONNECT LIQUID TUBE SUB-ASSEMBLY

HINT:  Use the same procedures described for the suction hose.

5. REMOVE INSTRUMENT PANEL SUB-ASSEMBLY

a. Remove the instrument panel.

6. REMOVE LOWER INSTRUMENT PANEL ASSEMBLY

a. Remove the instrument panel.

7. REMOVE AIR CONDITIONING AMPLIFIER ASSEMBLY

8. REMOVE ECM COVER

a. Detach the 2 claws and remove the cover.

9. REMOVE ECM

a. Disconnect the connectors.
b. Remove the 2 screws.
c. Detach the 2 claws and remove the ECM.