xA L4-1.5L (1NZ-FE) (2006)
e. Disconnect the suction hose.
NOTE:
-
Do not use tools, such as a screwdriver, to remove the tube.
-
Cap the open fittings immediately to keep moisture or dirt out of the system.
f.
Remove the 2 O-rings from the suction hose.
NOTE: Seal the openings of the disconnected parts using vinyl tape to prevent moisture and foreign matter from entering.
4. DISCONNECT LIQUID TUBE SUB-ASSEMBLY
HINT: Use the same procedures described for the suction hose.
5. REMOVE INSTRUMENT PANEL SUB-ASSEMBLY
a. Remove the instrument panel.
6. REMOVE LOWER INSTRUMENT PANEL ASSEMBLY
a. Remove the instrument panel.
7. REMOVE AIR CONDITIONING AMPLIFIER ASSEMBLY
8. REMOVE ECM COVER
a. Detach the 2 claws and remove the cover.
9. REMOVE ECM
a. Disconnect the connectors.
b. Remove the 2 screws.
c. Detach the 2 claws and remove the ECM.