Self diagnosis, V.A.G Inspection ServiceFault table
Fault table
Heating, ventilation, air conditioning system · Heating, air conditioning · Self-diagnosis of the Climatronic, vehicles: ¸% 05.00 · Alhambra from 1996 · Edition 04.2007
Note
- Climatronic control unit J255 and read from the vehicle diagnosis, testing and information system VAS 5051.
- .
- The fault table may also include the type of fault.
- vehicle diagnosis, testing and information system VAS 5051 and cleared.
- Chapter “Read measured value block” function. If necessary, perform complaint-related fault finding without self-diagnosis:
| Display on VAS 5051 | Possible cause of fault | Rectifying fault |
|---|
| 0 faults detected | If “0 faults detected” appears after repairs are completed, the self-diagnosis is ended. |
| 00532 | | |
| Voltage supply | | |
| Signal too large Note “Fault table” | Alternator defective | Check supply voltage using “Read measured value block” Chapter “Read measured value block” |
| Signal too small Note “Fault table” | Wiring or connectors to Climatronic control unit J255 | Check wiring and connectors to control unit using circuit diagram Current flow diagrams, Electrical fault finding and Fitting locations Check alternator Current flow diagrams, Electrical fault finding and Fitting locations |
| Display on VAS 5051 | Possible cause of fault | Rectifying fault |
|---|
| 00605 | | |
| Two-way valve for fresh air and air recirculation flap N63 | | |
| Open circuit/short to positive Note “Fault table” | Short circuit or open circuit in wiring or connectors to two-way valve for fresh air and air recirculation flap N63 | Check wiring and connectors using current flow diagram Current flow diagrams, Electrical fault finding and Fitting locations |
| Short to earth Note “Fault table” | Two-way valve for fresh air and air recirculation flap N63 defective | Replace two-way valve for fresh air and air recirculation flap N63 Chapter “Repairing Climatronic - dash panel area” |
| Display on VAS 5051 | Possible cause of fault | Rectifying fault |
|---|
| 00657 | | |
| Centre vent control motor V102 Note “Fault table” | | |
| Short circuit or open circuit in wiring or connectors to centre vent control motor V102 | Check wiring and connectors using current flow diagram Current flow diagrams, Electrical fault finding and Fitting locations |
| | Check function of control motor Chapter “Final control diagnosis” Functional test of the control motors |
| Central vent control motor V102 defective | Replace centre vent control motor V102 Chapter “Repairing Climatronic - dash panel area” |
| Display on VAS 5051 | Possible cause of fault | Rectifying fault |
|---|
| 00766 | | |
| Front vent temperature sender G152 | | |
| Open circuit/short to positive Note “Fault table” | Short circuit or open circuit in wiring or connectors to front vent temperature sender G152 | Check front vent temperature sender G152 using “Read measured value block” Chapter “Read measured value block” If faults are detected in ambient temperature sensor G17, sunlight penetration photosensor G107 or air conditioning system coolant temperature sender G110, first check wiring from control unit to connection -L56- (sender) in wiring harness for Climatronic. |
| Short to earth Note “Fault table” | Front vent temperature sender G152 defective | Check wiring and connectors using current flow diagram Current flow diagrams, Electrical fault finding and Fitting locations |
| | Replace front vent temperature sender G152 Chapter “Repairing Climatronic - dash panel area” |
| Display on VAS 5051 | Possible cause of fault | Rectifying fault |
|---|
| 00779 | | |
| Ambient temperature sensor G17 | | |
| | “- -” will appear in the ambient temperature display if ambient temperature sensor G17 fails |
| Open circuit/short to positive Note “Fault table” | Short circuit or open circuit in wiring or connectors to ambient temperature sensor G17 | Check ambient temperature sensor G17 using “Read measured value block” Chapter “Read measured value block” If faults are also detected in sunlight penetration photosensor G107, front vent temperature sender G152 or air conditioning system coolant temperature sender G110, first check wiring from control unit to connection L56 (sender) in wiring loom for Climatronic. |
| Short to earth Note “Fault table” | Ambient temperature sensor G17 defective | Check wiring and connectors using current flow diagram Current flow diagrams, Electrical fault finding and Fitting locations |
| | Renew ambient temperature sensor G17 Chapter “Repairing Climatronic - engine compartment” |
| Display on VAS 5051 | Possible cause of fault | Rectifying fault |
|---|
| 00792 | | |
| Air conditioning system pressure switch F129 Note “Fault table” | | |
| Short circuit or open circuit in wiring or connectors to air conditioning system pressure switch F129 | Check wiring and connectors using current flow diagram Current flow diagrams, Electrical fault finding and Fitting locations |
| Coolant pressure too high or too low due to: incorrect charging of refrigerant circuit or inadequate coolant cooling | Check air conditioning system pressure switch F129 using “Read measured value block 08” Chapter “Read measured value block”. |
| Air conditioning system pressure switch F129 defective | Renew air conditioning system pressure switch F129 Chapter “Repairing Climatronic - engine compartment” |
Note
ambient temperature sensor G17 malfunctions simultaneously.
| Display on VAS 5051 | Possible cause of fault | Rectifying fault |
|---|
| 00797 | | |
| Sunlight penetration photosensor G107 | | |
| Open circuit/short to positive | Open circuit or short circuit in wiring or connectors to sunlight penetration photosensor G107 | Check sunlight penetration photosensor G107 using “Read measured value block” Chapter “Read measured value block” If faults are detected in ambient temperature sensor G17, front vent temperature sender G152 or air conditioning system coolant temperature sender G110, first check wiring from control unit to connection -L56 (sender) in wiring harness for Climatronic. |
| Sunlight penetration photosensor G107 defective | Check wiring and connectors using current flow diagram Current flow diagrams, Electrical fault finding and Fitting locations |
| | Renew sunlight penetration photosensor G107 Chapter “Repairing Climatronic - dash panel area”. |
| Display on VAS 5051 | Possible cause of fault | Rectifying fault |
|---|
| 00799 | | |
| Air conditioning system coolant temperature sender G110 | | |
| Open circuit/short to positive Note “Fault table” | Open circuit or short circuit in wires or connectors to air conditioning system coolant temperature sender G110 | Check air conditioning system coolant temperature sender G110 using “Read measured value block” Chapter “Read measured value block” If faults are also detected in ambient temperature sensor G17, front vent temperature sender G152 and sunlight penetration photosensor G107, first check wiring from control unit to connection -L56 (sender) in wiring harness for Climatronic. |
| Short to earth Note “Fault table” | Air conditioning system coolant temperature sender G110 defective | Check wiring and connectors using current flow diagram Current flow diagrams, Electrical fault finding and Fitting locations |
| | Renew air conditioning system coolant temperature sender G110 Chapter “Repairing Climatronic - engine compartment” |
| Display on VAS 5051 | Possible cause of fault | Rectifying fault |
|---|
| 01086 | | |
| Speedometer sender G22 Note “Fault table” | Short circuit or open circuit in wiring or connectors from dash panel insert -K- to Climatronic control unit J255 | Check signal from speedometer sender G22 using “Read measured value block” Chapter “Read measured value block” Check wiring and connectors using current flow diagram Current flow diagrams, Electrical fault finding and Fitting locations |
| Speedometer sender G22 on gearbox defective (only if speedometer G21 is also not functioning) | Renew speedometer sender G22 |
A fault in
speedometer sender G22 has been detected The fault will be detected only if no speed signal is measured in 5 driving cycles within 2 minutes after the engine is started.
| Display on VAS 5051 | Possible cause of fault | Rectifying fault |
|---|
| 01184 | | |
| Rear vent temperature sender G174 | | |
| Open circuit/short to positive Note “Fault table” | Short circuit or open circuit in wiring or connectors to rear vent temperature sender G174 | Check rear vent temperature sender G174 using “Read measured value block” Chapter “Read measured value block” |
| Short to earth Note “Fault table” | Rear vent temperature sender G174 defective | Check wiring and connectors using current flow diagram Current flow diagrams, Electrical fault finding and Fitting locations |
| | Renew rear vent temperature sender G174 Chapter “Repairing Climatronic - 2nd evaporator” |
| Display on VAS 5051 | Possible cause of fault | Rectifying fault |
|---|
| 01185 | | |
| Rear fresh air blower V80 | | |
| Short circuit or open circuit in wiring or connectors to rear fresh air blower V80 | Check wiring and connectors using current flow diagram Current flow diagrams, Electrical fault finding and Fitting locations |
| | Check voltage at rear fresh air blower V80 using “Read measured value block” Chapter “Read measured value block” |
| Rear fresh air blower control unit J391 defective | Renew rear fresh air blower control unit J391 |
| Rear fresh air blower V80 defective | Renew rear fresh air blower V80 Chapter “Repairing Climatronic - 2nd evaporator” |
| Display on VAS 5051 | Possible cause of fault | Rectifying fault |
|---|
| 01186 | | |
| Rear air distribution control motor V136 Note “Fault table” | | |
| Short circuit or open circuit in wiring or connectors to rear air distribution control motor V136 | Check wiring and connectors using current flow diagram Current flow diagrams, Electrical fault finding and Fitting locations |
| | Check function of rear air distribution control motor V136 Chapter “Final control diagnosis” Functional test of control motors |
| Rear air distribution control motor V136 defective | Renew rear air distribution control motor V136 Chapter “Repairing Climatronic - 2nd evaporator” |
| Display on VAS 5051 | Possible cause of fault | Rectifying fault |
|---|
| 01187 | | |
| Rear temperature flap control motor V137 | | |
| Short circuit or open circuit in wiring or connectors to rear temperature flap control motor V137 | Check wiring and connectors using current flow diagram Current flow diagrams, Electrical fault finding and Fitting locations |
| | Check function of rear temperature flap control motor V137 Chapter “Final control diagnosis” Functional test of control motors |
| Rear temperature flap control motor V137 defective | Renew rear temperature flap control motor V137 Chapter “Repairing Climatronic - 2nd evaporator” |
| Display on VAS 5051 | Possible cause of fault | Rectifying fault |
|---|
| 01188 | | |
| Electrical connection for magnetic clutch control unit | | |
| Open circuit/short to positive Note “Fault table” | Short circuit or open circuit in wiring or connectors from Climatronic control unit J255 to air conditioning system magnetic clutch N25 | Check wiring and connectors using current flow diagram Current flow diagrams, Electrical fault finding and Fitting locations |
| Short to earth Note “Fault table” | In vehicles with VR 6 engine: magnetic clutch relay J44 defective In vehicles with all other engines: radiator fan control unit J293 defective | Renew magnetic clutch relay J44 or radiator fan control unit J293 Chapter “Repairing Climatronic - engine compartment” |
| Display on VAS 5051 | Possible cause of fault | Rectifying fault |
|---|
| 01189 | | |
| Centre flap control motor V70 is displayed in the vehicle diagnosis, testing and information system VAS 5051/ although front air distribution control motor V145 is installed | | |
| Short circuit or open circuit in wiring or connectors to front air distribution control motor V145 | Check wiring and connectors using current flow diagram Current flow diagrams, Electrical fault finding and Fitting locations |
| | Check function of front air distribution control motor V145 Chapter “Final control diagnosis” Functional test of control motors |
| Front air distribution control motor V145 defective | Replace front air distribution control motor V145 Chapter “Repairing Climatronic - dash panel area” |
| Display on VAS 5051 | Possible cause of fault | Rectifying fault |
|---|
| 01271 | | |
| Temperature flap control motor V68 Note “Fault table” | | |
| Short circuit or open circuit in wiring or connectors to temperature flap control motor V68 | Check wiring and connectors using current flow diagram Current flow diagrams, Electrical fault finding and Fitting locations |
| | Check function of temperature flap control motor V68 Chapter “Final control diagnosis” Functional test of control motors |
| Temperature flap control motor V68 defective | Renew temperature flap control motor V68 Chapter “Repairing Climatronic - dash panel area” |
| Display on VAS 5051 | Possible cause of fault | Rectifying fault |
|---|
| 01273 | | |
| Fresh air blower V2 | | |
| Short circuit or open circuit in wiring or connectors to fresh air blower V2 | Check wiring and connectors using current flow diagram Current flow diagrams, Electrical fault finding and Fitting locations |
| | Check voltage at fresh air blower V2 using “Read measured value block” Chapter “Read measured value block” |
| Fresh air blower control unit J126 defective | Renew fresh air blower control unit J126 |
| Fresh air blower V2 defective | Renew fresh air blower V2 Chapter “Repairing Climatronic - dash panel area” |
| Display on VAS 5051 | Possible cause of fault | Rectifying fault |
|---|
| 65535 | | |
| Control unit faulty | Electrical interference caused by outside sources, poor earth connections or positive connections to Climatronic control unit J255 | Check wiring and connectors to Climatronic control unit J255 using current flow diagram Current flow diagrams, Electrical fault finding and Fitting locations |
| Dash panel temperature sensor G56 defective. Temperature sensor blower V42 defective | Check dash panel temperature sensor G56 using “Read measured value block” Chapter “Read measured value block” |
| Climatronic control unit J255 defective | Renew Climatronic control unit J255 if necessary Chapter “Repairing Climatronic - dash panel area” |
02 Diagnostics