Checking specific gravity
- Make
- SEAT
- Model
- Alhambra
- Year
- 1996–2010
- Section
- Electrical system › Checking specific gravity
Checking specific gravity
- Commercially available hydrometer

Check battery electrolyte level Chapter “Low maintenance battery: checking”.
Switch off ignition and all electrical consumers.
Pull protective foil off cell plugs, if fitted.
Note!
- The stickers with the warning notices must remain on the battery.
Remove cell plugs.
Draw off sufficient electrolyte from one cell to ensure the float swims.
The specific gravity (density) of the fluid determines the depth that the float swims. The value can be read on the scale on the float.
| Specific gravity | Charge | Voltage |
|---|---|---|
| 1.28 g/cm 3 | 100 % | 12.7 V |
| 1.21 g/cm 3 | 60 % | 12.3 V |
| 1.18 g/cm 3 | 40 % | 12.1 V |
| 1.10 g/cm 3 | 0 % | 11.7 V |
Note!
- Checking the specific gravity directly after replenishing with distilled water leads to faulty readings. Check specific density directly after charging the battery.
Check cell plugs and O-rings for damage. Damaged parts must be renewed.
Seal cells with cell plugs.