Time period of the Coming Home function: adapting
- Make
- SEAT
- Model
- Altea / Altea XL / Freetrack
- Year
- 2004–2015
- Section
- Electrical system › Time period of the Coming Home function: adapting
Time period of the Coming Home function: adapting
Coming Home Function: Length of time during which lighting stays on, after leaving vehicle.
The illumination time of the Coming Home function may be adjusted to vary between 0 and 120 seconds.
Connecting the vehicle diagnostic, testing and information system VAS 505X
Select the mode of operation vehicle diagnostic, testing and information system VAS 505X in the “Guided Fault Finding”.
Select the entry “Component and function selection” using the button “go to” and then the successive menu points:
- Body
- Electrical system
- 01 - Self-diagnosis-compatible systems
- Control unit for the onboard network
- Functions of the onboard power supply control unit
- Adapt the time of the Coming Home function
Parts & tools for this job For 2004 SEAT Altea
- TOOLDigital multimeterSearch: automotive digital multimeter
- PARTAssorted fuse kitSearch: car fuse assortment kit
- TOOLWire crimper and connector kitSearch: wire crimper connector kit