01 Self diagnosis, V.A.G Inspection Service02 Engine assy, cylinder block, crankcase03 Enginecrankshaft group, pistons04 Engine cylinder head, valve gear05 Engine lubrication06 Engine cooling07 Fuel supply, gas operation08 Exhaust turbocharger, G-charger09 Fuel preparation system Diesel injection10 Mixture preparation system, electronic inj., Gas11 Exhaust system12 Starter-current supply-CC13 Ignition system, glow plug system14 Clutch, control15 Torque converter16 Gearbox mechanics, operation, construction, diff.17 Gearbox, mechanics, gears, shafts, internal operation18 Automatic gearbox, control, assembly, housing19 Automatic gearbox, gears, control20 Final drive, differential, differential lock21 Front suspension, drive shafts22 Rear suspension, drive shaft23 ABS, ADR, TCS, EDL, ESP24 Brake, brake mechanics25 Brakes, hydraulics, regulator, servo26 Steering27 Body front28 Body centre, roof, frame29 Body, rear30 Bonnet, flaps, cab, central locking31 Front door, central locking32 Rear door, sliding door, wing doors, central locking33 Sliding roof34 Bumper35 Glazing/window mechanism36 Exterior equipment37 Interior equipment38 Passenger protection39 Trim, noise insulation40 Seat frames41 Seat padding, covers42 Heating43 Air conditioner44 Infotainment45 Windscreen wipe/wash system46 Lights, lamps, switches outside47 Wiring
SEAT Ibiza / Córdoba / Vario (6K, 1993-2002)01 · Self diagnosis, V.A.G Inspection Service
01 · Diagnostics

Fault table

Make
SEAT
Model
Ibiza / Córdoba / Vario
Year
6K, 1993–2002
Section
Heating, air conditioning › Fault table
Self diagnosis, V.A.G Inspection ServiceFault table

Fault table

Heating-ventilation-air conditioning system · Heating, air conditioning · Autoclima self-diagnosis, electrical checking · Ibiza / Córdoba / Vario from 2000 · Edition 07.00

Note!

  • J255, which are printed in the V.A.G 1551, ordered according to the 5 digit fault codes.
  • (
    ).
  • The fault code only appears on the printout.
  • The fault type may also appear on the fault table.
  • fault reader V.A.G 1551 must always be cleared and consulted once more.
  • (Chapter “Activator diagnosis 03”) must be carried out, as well as the function
    (Chapter “Read measurement value block 08”). If the display should blink, even though no fault has been detected, the functions must both be carried out, one after the other. If necessary, a fault localisation will have to be undertaken ⇒ Fault localisation Heating, air conditioning.
Printout in V.A.G 1551 printerPossible cause of the faultFault elimination
00000

No fault detected


If after carrying out the repair “No fault detected” appears, the self-diagnosis is at an end.
If the display continues to blink, the following functions must be performed one after the other:
04 Begin basic adjustment Chapter “Basic adjustment 04”
00532
Supply voltage





Signal too small / SP Note “Fault table”


Alternator faulty




Cables or connectors to the Autoclima control unit J255


Check the supply voltage (voltage on terminal 15) by “read measurement value block 08”
Chapter “Read measurement value block 08”

Check the alternator:
Current flow diagrams, Electrical fault finding and Fitting locations

Check the supply voltage (voltage on terminal 15) by “read measurement value block 08” Anchor “Table of the measurement values” Check the cables and connectors against the current circuit diagram
Check the alternator:Current flow diagrams, Electrical fault finding and Fitting locations

Note

Printout in V.A.G 1551 printerPossible cause of the faultFault elimination
00600

Potentiometer G92 in the servomotor V68 (for temperature sensor) Note “Fault table”
Short-circuit against ground /SP.Interruption short-circuit against positive /SP.Self-adaptation limit exceeded Note “Fault table”
Short-circuit, cable breakage or error in the contacts of the connectors between G92 and J225.Temperature sensor moving with difficulty.Potentiometer G92 in V68, faulty.Locate and eliminate the short-circuit, the cable breakage or the error in the contacts of the connectors, by following the current circuit diagram.Check the freedom of movement of the temperature sensor Note “Fault table”.Replace the servomotor V68.

Note

G92, by pressing the keys
or
to pre-select the temperature, the servomotor may be adjusted manually V68 (indication margin between 0º C and 50º C).

Note

Note

Printout in V.A.G 1551 printerPossible cause of the faultFault elimination
00625

Speed signal.
Signal mot plausible /SP.
Loose contact in the wiring between the speed transmitter G68, the instrument panel or other component also connected to the signal (e.g. Autorradio or control unit for GRA) of the E87.The tachometer G21 or the instrument panel supplies a useless signal or one of the components connected destroys the signal.Locate and eliminate the loose connection following the current circuit diagram.Check the speed signal of the transmitter G21 or the instrument panel (check all the components connected to this data transmission line). Electrical system Rep. Gr. 90
00716


Servomotor for circulating air flap
V113 Note “Fault table”



Short circuit or breakage in the cables or connectors to the servomotor for the circulating air flap V113
V113 blocked





V113 faulty


Check V113 by “read measurement value block” Chapter “Read measurement value block 08”
Check cables and connectors along the current circuit diagram
Carry out activator diagnosis 03 Anchor “Basic adjustment 04”
Replace V113 and begin function 04 “Basic adjustment”.

Note

Printout in V.A.G 1551 printerPossible cause of the faultFault elimination
00779

External temperature sensor G17

Interruption/short circuit to positive Note “Fault table”

Short circuit to ground Note “Fault table”



Short circuit to positive or break in the cable or connectors of the external temperature sensor G17


Short circuit to ground in cables or connectors to the external temperature sensor G17.


G17 faulty


Check G17 by “read measurement value block” Chapter “Read measurement value block 08” Check cables and connectors following the current circuit diagrams
Check G17 by “read measurement value block” Chapter “Read measurement value block 08” Check cables and connectors following the current circuit diagrams
Replace G17

Note

Printout in V.A.G 1551 printerPossible cause of the faultFault elimination
00785

Control panel thermosensor G56.
Short circuit against ground /SP.Interruption, short circuit against positive /SP.
Short circuit or cable break between G56 and J255.Thermosensor G56, faulty.Locate and eliminate the short circuit or the break in the cables following the current circuit diagram.Check the thermosensor G56 (electrical verification, Anchor “Table of the measurement values”)
00792

Pressure gauge for the air conditioner F129.
Short circuit to ground /SP.
Brake in the wiring connection between F129 and E87.Fault in the activation of the fan for the cooling fluid V7 (step 1).Dirty condenser or radiator.Fault in the activation of the fan for the cooling fluid V7 (step 2) of the pressure gauge F129.Pressure gauge F129, faulty.Fault in the cooling agent circuit (overload or depression).Locate and eliminate the short circuit or the loose contact following the current circuit diagram.Check the activation of the fan V7 (step 1) : activator diagnosis, Chapter “Activator diagnosis 03” electrical verification, Anchor “Table of the measurement values”.Clean the condenser and the radiator.Check the activation of the fan for the cooling fluid V7 (step 2, by means of pressure gauge F129), and the control unit for the cooling fluid fan J293.Check the pressure gauge F129 (Chapter “Replacing the control unit for the cool air ventilator J126”).

Note!

  • F129 is composed of two control elements:

By means of contacts 1 and 2, the compressor will be disconnected if there is depression or overload in the cooling agent circuit the switch opens the passage).

By means of contacts 3 and 4 the fan for the cooling fluid is connected to the 2nd step (the switch closes the passage).

Printout in V.A.G 1551 printerPossible cause of the faultFault elimination
00796

Ventilator for the thermal probe of the instrument panel V42.
Blockage or lack of voltage /SP.
Break in the voltage supply to V42 or in the wiring between V42 and E87.Blower V42, faulty.Locate and eliminate the break in the wiring following the current circuit diagram.Replace blower V42.
01271

Servomotor for the temperature flap V68 Note “Fault table”


Short circuit of break in the wiring or connectors to the servomotor for the temperature flap V68

The V68 has been fitted without carrying out the function “04 Begin basic adjustment”.

V68 blocked

V68 faulty


Check V68 by “read measurement value block” Chapter “Read measurement value block 08” Check cables and connectors along the current circuit diagram
Check the final position of the servomotor V68, once fitted Anchor “Table of the measurement values” Carry out diagnosis of the activators 03 Chapter “Activator diagnosis 03” Replace V68 and commence function 04 “basic adjustment”.

Note

Printout in V.A.G 1551 printerPossible cause of the faultFault elimination
01273

Cool air fan V2 or control unit for the cool air fan J126


Short circuit or break in cables or connectors to the cool air ventilator V2


Control unit for fan J126 or cool air ventilator V2 faulty


Check V2 by “read measurement value block” Chapter “Read measurement value block 08” Check cables and connections along the current circuit diagrams
Carry out activator diagnosis 03 Chapter “Activator diagnosis 03”
Replace J126 ó V2
01296

Temperature transmitter in central diffuser G191


Break / short circuit to positive


Short circuit to ground






There is no transmitter for the central temperature diffuser G191






Then select the following function:04 Begin basic adjustment
Chapter “Basic adjustment 04”
01297

Temperature transmitter of the footrest area diffuser G192

Break / short circuit to positive




Short circuit to ground





Short circuit to ground or break in the cables or connectors to the temperature transmitter of the footrest area diffusers G192



Short circuit to ground or break in the cables or connectors to the temperature transmitter of the footrest area diffusers G192


G192 defective





Check the G192 by “read measurement value block” Chapter “Read measurement value block 08” Check the cables and connector along the current circuit diagrams.
Check the G192 by “read measurement value block” Anchor “Table of the measurement values” Check the cables and connector along the current circuit diagrams.Replace G192
65535

Control unit J255


Cables or connectors to the control unit for Autoclima J255






Control unit for Autoclima defective


Check the cables and connector along the current circuit diagrams.Check the control unit for Autoclima J255 by “read measurement value block” Chapter “Read measurement value block 08”

Replace the control unit for Autoclima J255. The select the following function:
04 Begin basic adjustment Chapter “Basic adjustment 04”

Parts & tools for this job For 1993 SEAT Ibiza