01 Technical data02 Self diagnosis, V.A.G Inspection Service03 Engine assy, cylinder block, crankcase04 Enginecrankshaft group, pistons05 Engine cylinder head, valve gear06 Engine lubrication07 Engine cooling08 Fuel supply, gas operation09 Exhaust turbocharger, G-charger10 Fuel preparation system Diesel injection11 Mixture preparation system, electronic inj., Gas12 Exhaust system13 Starter-current supply-CC14 Ignition system, glow plug system15 Clutch, control16 Gearbox mechanics, operation, construction, diff.17 Gearbox, mechanics, gears, shafts, internal operation18 Final drive, differential, differential lock19 Front suspension, drive shafts20 Rear suspension, drive shaft21 Wheels, tyres. axle align22 ABS, ADR, TCS, EDL, ESP23 Brake, brake mechanics24 Brakes, hydraulics, regulator, servo25 Steering26 Body front27 Body centre, roof, frame28 Body, rear29 Bonnet, flaps, cab, central locking30 Front door, central locking31 Rear door, sliding door, wing doors, central locking32 Sliding roof33 Bumper34 Glazing/window mechanism35 Exterior equipment36 Interior equipment37 Passenger protection38 Trim, noise insulation39 Seat frames40 Seat padding, covers41 Heating42 Air conditioner43 Instruments, GCI44 Infotainment45 Windscreen wipe/wash system46 Lights, lamps, switches outside47 Lights, lamps, switches inside, anti-theft system48 Wiring
SEAT Ibiza (6J, 2008-2017)42 · Air conditioner
42 · Heating & A/C

Safety measures when handling refrigerant

Make
SEAT
Model
Ibiza
Year
6J, 2008–2017
Section
Heating, air conditioning › Safety measures when handling refrigerant
Air conditionerSafety measures when handling refrigerant

Safety measures when handling refrigerant

Heating, ventilation, air conditioning system · Heating, air conditioning · Instructions for repair work on vehicles with air conditioning and how to work with the refrigerant · Ibiza from 2008 · Edition 08.2014

The following safety measures are to be observed in Germany for this refrigerant (additional regulations may apply in other countries).

The refrigerant circuit must be discharged first should repair work require the refrigerant circuit to be opened Chapter “Safety precautions”. All contact with liquid refrigerant or refrigerant vapours should be avoided. Should refrigerant escape although all safety measures are observed, do not inhale the mixture of refrigerant and air which then forms.

Therefore, switch on extraction systems and wear rubber gloves and protect eyes with safety goggles.

Reasons:

Intensive exposure to refrigerant would cause frostbite on unprotected parts of the body.

Warning

It is recommended that you always have an eye-bath ready for use in case it is needed.

Should liquid refrigerant come into contact with the eyes, rinse them thoroughly with water for about 15 minutes.

Then apply eye drops and consult a doctor immediately, even if you do not experience any pain in the eyes.

Always inform the doctor of the type of refrigerant involved.

Should refrigerant come into contact with other parts of the body even though all safety measures have been observed, these components must also be thoroughly rinsed with cold water immediately for at least 15 minutes.

Although refrigerants do not represent a fire hazard, smoking, welding, soldering and brazing are not permitted in areas exposed to refrigerant.

Reasons:

The high temperature of a naked flame or hot objects causes decomposition of refrigerant gas. Inhalation of the toxic decomposition products causes dry coughing and nausea.