Activation of supplementary heating system (on vehicles without air conditioner)
Note
- heating control unit J65). The activation of the electric additional heating is performed by the additional air heating control unit J604 or the engine control unit (in 3 phase version through the low temperature relay J359 and the high temperature relay J360) Vehicle diagnostic, testing and information system VAS 505X (fault finding assisted by the relevant engine control unit) and Current flow diagrams, Electrical fault finding and Fitting locations
- heater element for additional air heater Z35 is activated via the additional air heating control unit J604. Vehicles with diesel engine manufactured from November 2006 (gradual conversion) are fitted with a 3-stage supplementary heater element Z35; this is actuated by the corresponding engine control unit via a relay Current flow diagrams, Electrical fault finding and Fitting locations and the vehicle diagnostic, testing and information system VAS 505X(Guided fault finding for corresponding engine control unit).
- additional air heating control unit J604 is described in the guided fault finding of the air conditioner and in the vehicle diagnostic, testing and information system VAS 505X.
- additional air heating control unit J604 indicates whether the additional heating activates or, if not, why it does not when a request is made and Vehicle diagnostic, testing and information system VAS 505X.
- heater element for additional air heater Z35 is described in the guided fault finding of the respective engine control unit vehicle diagnostic, testing and information system VAS 505X.
- For vehicles with a petrol engine, no additional heating is fitted.
- 105-pin tester box V.A.G 1598/42-1

- Vehicle diagnostic, testing and information system VAS 505x

- Multimeter cables VAS 5051/7
- heater control unit J65. This switch can be moved (closed) to the limit using the rotary switch for selecting the temperature (A) in the scope of the adjustment of approx. 3 hours.

If the heating switch is closed, the electronics of the Heating control unit J65, with the ignition on, connects through pin „7“ earth to the Additional air heating control unit J604. The Additional air heating control unit J604 detects that more heating power is required and activates the additional electric heating, if the remaining conditions for activation are fulfilled in the Additional air heating control unit J604.

- heating element for additional heating Z35) of the additional air heating control unit J604
- auxiliary heater control unit J364) on vehicles equipped with this optional extra Auxiliary heater Rep. gr.
- heating element for additional heating Z35) of the relevant engine control unit Vehicle diagnostic, testing and information system VAS 505X (Guided Fault Finding for corresponding engine control unit).
Note
- heating element for additional heating Z35 with three phases via the low temperature relay J359 and the high temperature relay J360, the same conditions must be met in the engine control unit as in the air conditioning control unit J301 in vehicles with manual climate control.
Engine control unit actuates auxiliary air heater element J359 via low heat output relay J360 and high heat output relay Z35 if the following conditions are met:
- Heater control unit J65 applying earth signal to engine control unit
- Engine running for at least 8 seconds and engine speed above 500 rpm
- The engine temperature is below 75 °C
- Calculated ambient temperature is lower than 8° C
- onboard supply control unit J519 not transmitting any request preventing activation
- alternator C less than 30 .. 77 % (depending on engine speed)
Note
- heater element for additional air heater Z35, the engine control unit activates both relays for the additional heating in such as way that the loading of the alternator C does not exceed 95 %. Vehicle diagnostic, testing and information system VAS 505X (for the relevant engine control unit) and Current flow diagrams, Electrical fault finding and Fitting locations. The following phase only connects when the alternator C stress is below 30 ..77% (depending on engine speed)
Note
- Vehicles without air conditioning cancel the activation if the engine control unit fails to meet the connection criteria, or detects one of the disconnection criteria.
- If one of the connection conditions is lost
- Calculated ambient temperature is more than 11° C.
- alternator C greater than 95 %.
- Heater control unit J65 no longer applying earth signal to engine control unit
Parts & tools for this job For 2008 SEAT Ibiza