Workshop Manuals Factory service & repair SEAT
01 Technical data02 Self diagnosis, V.A.G Inspection Service03 Engine assy, cylinder block, crankcase04 Enginecrankshaft group, pistons05 Engine cylinder head, valve gear06 Engine lubrication07 Engine cooling08 Fuel supply, gas operation09 Exhaust turbocharger, G-charger10 Fuel preparation system Diesel injection11 Mixture preparation system, electronic inj., Gas12 Exhaust system13 Starter-current supply-CC14 Ignition system, glow plug system15 Clutch, control16 Gearbox mechanics, operation, construction, diff.17 Gearbox, mechanics, gears, shafts, internal operation18 Final drive, differential, differential lock19 Front suspension, drive shafts20 Rear suspension, drive shaft21 Wheels, tyres. axle align22 ABS, ADR, TCS, EDL, ESP23 Brake, brake mechanics24 Brakes, hydraulics, regulator, servo25 Steering26 Body front27 Body centre, roof, frame28 Body, rear29 Bonnet, flaps, cab, central locking30 Front door, central locking31 Rear door, sliding door, wing doors, central locking32 Sliding roof33 Bumper34 Glazing/window mechanism35 Exterior equipment36 Interior equipment37 Passenger protection38 Trim, noise insulation39 Seat frames40 Seat padding, covers41 Heating42 Air conditioner43 Instruments, GCI44 Infotainment45 Windscreen wipe/wash system46 Lights, lamps, switches outside47 Lights, lamps, switches inside, anti-theft system48 Wiring
SEAT Ibiza (6J, 2008-2017)25 · Steering
25 · Steering & suspension

Electro-hydraulic pump reservoir: removing and installing

Make
SEAT
Model
Ibiza
Year
6J, 2008–2017
Section
Running gear, axles, steering › Electro-hydraulic pump reservoir: removing and installing
SteeringElectro-hydraulic pump reservoir: removing and installing

Electro-hydraulic pump reservoir: removing and installing

Running gear · Running gear, axles, steering · Hydraulic pump, tank, hydraulic lines · Ibiza from 2008 · Edition 02.2015

Consult the equivalence table for tools and equipment according to applicability between Seat / VW / Audi / Skoda Chapter “Equivalency table according to usability”.

W00-2718
  • Protective gloves (commercially available)
  • Rubber head hammer (commercially available)

Note

  • Absolute cleanliness is required when replacing the reservoir.
  • Before separating, thoroughly clean entire circumference between the connecting point for the return run on the tank and pressure line connection on the electro-hydraulic pump unit. Do not use aggressive cleaning agents such as, e.g. brake cleaner, petrol, thinner or the similar.
  • Place parts that have been removed on a clean surface and cover them.
  • If repairs cannot be carried out immediately, carefully cover open components.
  • Do not use cloths with loose threads
  • Only take spares out of their packaging just before assembly.
  • Only use replacement parts which come in their original packaging.
  • The application surface of the tank and electro-hydraulic pump unit should not come into contact with any type of adhesives.

Removing reservoir

Remove the electro-hydraulic pump Chapter “Electro-hydraulic pump, remove and install”.

Residual amounts of fluid will remain in the electro-hydraulic pump unit after extracting the hydraulic fluid.

Seal the threaded connection for the pressure line on the electro-hydraulic pump unit.

Remove the bracket of the electro-hydraulic pump.

Open clamp (1) and remove upwards.

N48-10237

Warning

Wear protective gloves when heating and pulling off the reservoir.

Heat the bottom part of the tank (2) all around using the hot-air blower SAT 1416, for example.

Warning

The reservoir may only be heated to a maximum of 80 °C.

Unplug the connector (2) from the electro-hydraulic pump (3).

Installing reservoir

Note

  • Make sure that the application surface of the electro-hydraulic pump and the sealing ring of the tank is clean and free of oil and grease.
  • When installing the tank in the electro-hydraulic pump, never use lubricants or grease.
  • The application surface of the tank and electro-hydraulic pump unit should not come into contact with any type of adhesives.

Fit a new seal on the sealing surface of the electro-hydraulic pump: allocation Electronic parts catalogue “ETKA”.

Ensure oil seal is seated correctly.

Warning

Wear protective gloves when heating and fitting the reservoir.

Heat the bottom part of the new tank all around using the hot-air blower SAT 1416, for example.

Warning

The reservoir may only be heated to a maximum of 80 °C.

Mount the tank (1) onto the electro-hydraulic pump (2).

N48-10238

Position reservoir so that the union for the return line (arrow A) is vertically over the union for the pressure line (arrow B).

Press t the tank (1) onto the electro-hydraulic pump (2) as far as it will go.

Use a rubber head hammer to tap evenly all around the reservoir (1) when doing this, never hit the filling support with the hammer.

Ensure the reservoir is not canted.

Fix the tank to the electro-hydraulic pump using a new clamp Electronic parts catalogue “ETKA”.

Tighten the bolt of the clamp to a tightening torque of 3 Nm.

Reconnect return line union to motor/pump unit.

Fill reservoir to approx 1/4 full with hydraulic fluid and check for leaks between the connecting area of reservoir to the electric-hydraulic pump unit.

Tighten clamp if leaks are found.

Drain reservoir.

The changing of the reservoir must be documented for reasons of guarantee.

Mark an area of approx 15 x 30 mm with a permanent coloured mark (2) e.g. anti-tamper paint at the position as illustrated.

N48-10239

The marking must be made on the tank (1), the clamp (3) and the electro-hydraulic pump (4).

Install the bracket of the electro-hydraulic pump.

Open the connecting support mounted on the tank for return line and the threaded support for the pressure line on motor/pump unit.

Install the electro-hydraulic pump Chapter “Electro-hydraulic pump, remove and install”.

Specified torques

ComponentTightening torque
Clamp at reservoir of engine pump aggregate Use new clamp3 Nm

Parts & tools for this job For 2008 SEAT Ibiza

As an Amazon Associate we earn from qualifying purchases.