seat Workshop Repair Guides

SEAT Workshop Service and Repair Manuals

Test table > < Initiating basic setting
Self-diagnosis for 5-speed automatic gearbox 09B
Read measured value block
Read measured value block

Additional information

  • ◆ Workshop manual Alhambra 1996 ▸ 5-speed automatic gearbox 09A
  • ‒ Connect VAS 5051 and continue to switch until the diagnosis functions are displayed => Performing self-diagnosis; 01-11.
  • ‒ Press 08 - Read measured value block
  • ‒ Press the number for the display group that you want to see.
  • ‒ Enter display group number => List of selectable display group numbers, 01-35.
  • ‒ Confirm entry with key Q.
  • ‒ There are always 4 display zones in the measured value block (if necessary, in physical quantities). Interpreting the values in display zones 1 to 4 =>Test table 01-39.

List of selectable display group numbers

Indicated on display (example)

Display zones are ordered vertically

Display group No.

Display zone

Description

Read measured value block
28 km/h
1790 rpm
1730 rpm
2

001

1 =
2 =
3 =
4 =

Road speed
Gearbox input speed sender -G182-
(turbine rpm)
Engine speed
Selected gear

Read measured value block
0 %
34 %
30.0°C
14.1V

002

1 =
2 =
3 =
4 =

Accelerator pedal value
Solenoid valve 6 -N93- (regulation in %)
ATF temperature
Battery voltage

Read measured value block
0 km/h
D
1
4 %

003

1 =
2 =
3 =
4 =

Road speed
Selector lever position
Selected gear
Solenoid valve 4 -N91- (regulation in %)

Read measured value block
D
00001000
01000000
00000110

004

1 =
2 =
3 =
4 =

Selector lever position or current Tiptronic situation: TIP M, T+, T-
Multi-function switch (8 character display)
Switch position (8 character display)
Switch output (8 character display)

Indicated on display (example)

Display zones areordered vertically

Display group No.

Display zone

Description

Display group number

005

available:

from program level 0035

Read measured value block
D
TIP M
3 M
010 0110

005

1 =
2 =
3 =
4 =

Selector lever position
Current Tiptronic situation
Gear selected
Switch positions (4th character is vacant)
Position 1-3: characters displayed here must equate to current Tiptronic situation as per display zone 2:
010 must be displayed for TIP M
011 must be displayed for TIP +
110 must be displayed for TIP -
Position 5-8: Multi-function switch

Read measured value block
+/- 08 %
008 %
008 %
030 %


006


1 =
2 =
3 =
4 =

Disregard
Driving resistance, calculated as a gradient
Hill factor
Sports factor
Accelerator pedal value

Indicated on display (example)

Display zones are ordered vertically

Display group No.

Display zone

Description

Display group number

007

available:

from program level 0035

Read measured value block
1790 rpm
1730 rpm
0 rpm
20 km/h

007

1 =
2 =
3 =
4 =

Engine speed
Gearbox input speed sender -G182-
(turbine speed)
Intermediate shaft speed sender -G265-
Road speed sender -G68-

Display group number

008

available:

from program level 0035

Read measured value block
0 %
34 %
90 %
2 H

008


1 =
2 =
3 =
4 =

Disregard
Accelerator pedal value (engine control unit signal)
Solenoid valve 6 -N93- (main pressure control in %)
Solenoid valve 10 -N283- (pressure regulation, 2-4 gear brake in %)
Gear selected

Indicated on display (example)

Display zones are ordered vertically

Display group No.

Display zone

Description

Read measured value block
SME-R
00.00.00
00030
1 0344


080


1 =
2 =
3 =
4 =

Disregard
Manufacturer's data
Manufacture date of control unit
Eprom program version
Manufacturer's data

Display group number

125

available:

from program level 0035

Read measured value block
ENGINE 1
BRAKE 1
COMBI 1
...

125


1 =
2 =
3 =
4 =

Disregard
Engine control unit on data bus
Brake control unit on data bus
Combi-instrument control unit on
data bus
Other control units if installed

Test table > < Initiating basic setting