Exhaust gas recirculation system
Checking exhaust gas recirculation valve (mechanical)

Special tools, testers and auxiliary items

  • ◆ Hand vacuum pump V.A.G 1390

Test sequence

  • ‒ Pull vacuum hose off (mechanical) exhaust gas recirculation valve.
  • ‒ Connect hand vacuum pump V.A.G 1390 to valve.
 
V26-0821
  • ‒ → Operate pump.
        The membrane rod must move towards
        vacuum connection (observe membrane rod
        via opening -arrow-).
  • ‒ Pull hand vacuum pump hose of exhaust gas recirculation valve.
        The valve must clearly heard to close (membrane rod moves
        towards intake manifold).