seat Workshop Repair Guides

SEAT Workshop Service and Repair Manuals

Prerequisites > < Control unit for heating and fresh air: dismantling and assembling
Actioning cable: mounting and adjusting
   
Actioning cable: mounting and adjusting
  Note!
t  First mount the actioning cables in the dismounted control unit and then adjust and fix the cables on the levers
t  Covers of actioning cables are differently coloured
t  Check actioning cables before mounting and substitute tight moving cables or those that present imperfections
t  On turning controls all flaps should audibly reach max. position
1 - Actioning cable for the footwell zone/ deicer flap
q   From the control knob of air distributor to the footwell zone flap/deicer
q   Identification of the cover of the actioning cable: Left hand drive: black Right hand drive: black
q   Adjusting the actioning cable in the footwell zone/deicer flap → Fig.
2 - Actioning cable for central flap
q   Of the air distributor control knob to the central flap
q   Identification of the cover of the actioning cable: Left hand drive: yellow Right hand drive: grey
q   Adjust the actioning cable in central flap → Fig.
3 - Actioning cable for temperature flap
q   From the temperature control knob to the temperature flap
q   Identification of the cover of the actioning cable: Left hand drive: blue Right hand drive: white
q   Adjust the actioning cable in temperature flap → Fig.

   
Adjust actioning cable in footwell/deicer flap
  N80-0037

Prerequisites > < Control unit for heating and fresh air: dismantling and assembling